5.1.2 Environmental Conditions Sections 5.1.2.15 -
5.1.2.20
-
5.1.2.15 Solar radiation. Requirements for solar
radiation shall be as specified herein.
5.1.2.15.1 Fully hardened.
Exposed equipment shall not be damaged and shall maintain specified
performance when exposed to the sun at its service location. Equipment shall
be tested in accordance with MIL-STD-810, method 505, procedure II.
5.1.2.15.2 Minimal acceptance. Generally, requirements for solar
radiation are not applicable. Requirements for equipment operation under solar
radiation shall be specified only for those installations determined by the
specifier to be subject to solar radiation.
5.1.2.16 Spray tight
enclosures. Requirements for equipment enclosures to withstand spray from
ruptures or discharges from adjacent high pressure fittings are as follows:
5.1.2.16.1 Fully hardened. Requirements shall be tailored from
MIL-STD-108. Typical applications include submarines and hazardous locations.
5.1.2.16.2 Minimal acceptance. General, requirements for spray tight
enclosures is not applicable to equipment installed in controlled spaces.
5.1.2.17 Temperature
ranges. Requirements for temperature shall be as specified herein. Temperature
tests shall be in accordance with MIL-STD-810, methods 501 and 502, procedure
I. Safety criteria shall be as specified in 5.1.3.11.9. The specified criteria for equipment
installed in controlled spaces shall take into account failure of the
environmental control system for up to 8 hours duration.
5.1.2.17.1
Fully hardened. Equipment temperature requirements for shipping and operating
shall be tailored from Table III.
5.1.2.17.2 Minimal acceptance.
Equipment temperature requirements for shipping and operating shall be
tailored from Table IV. Equipment shall not be damaged when ambient conditions
are outside nominal operating limits.
5.1.2.18 Underwater explosion.
Requirements for underwater explosion shall be as specified herein.
5.1.2.18.1 Fully hardened. Equipment which is submerged and exposed to
external sea pressure shall withstand the underwater explosion test in
accordance with MIL-S-901 for wetted-surface type mounted items.
5.1.2.18.2 Minimal acceptance. Generally, requirements for underwater
explosion are not applicable. Requirements for equipment operation underwater
explosion conditions shall be specified only for those installations
determined by the specifier to be subjected to underwater explosions.
5.1.2.19 Vibration. Requirements for vibration shall be as specified
herein.
5.1.2.19.1 Fully hardened and minimal acceptance. Shipboard
equipment shall be in accordance with the type I vibration requirements of
MIL-STD-167-1.
5.1.2.20 Wind effects. Requirements for wind effects shall be as specified
herein.
5.1.2.20.1 Fully hardened. The exposed equipment, or
portions thereof, shall operate within performance limits in winds having a
relative velocity of 140 km/hr (75 knots) with gusts up to 250 kilometers per
hour (130 knots), and shall withstand, without damage, winds having a relative
velocity as great as 185 km/hr (100 knots) with gusts up to 325 km/hr (175
knots).
5.1.2.20.2 Minimal
acceptance. Generally, requirements for wind effects are not applicable.
Requirements for equipment operation under wind effects shall be specified
only for those installations determined by the specifier to be subject to